Water pump: Presence of rust /contamination from foreign matter

Causes:
  • Incorrect cleaning of the system
  • High percentage of chlorine in the coolant
  • Use of pure water without coolant
  • Water is too hard, with high percentage of limestone
Actions:
  • Thoroughly clean the system
  • Use distilled water mixed with coolant
  • Replace the faulty/damaged component